CADSolver automated design review

L-Bracket 0.125in

Part number
LB-0125-4H
Revision
A
Material
mild steel
Reviewed
2026-09-03 16:48:39 UTC
Source body
session handle 51665988_solid_10

Laser cut + press brake. Bend radius 3.119 mm, K=0.370 (SCS mild steel row). 4x Ø7.14 mm (17/64) clearance holes for 1/4-20.

At a glance

Errors

0

error-severity findings

Warnings

0

warning-severity findings

Notes

1

info-severity findings

Stages run

6/6

0 failed, 0 skipped

Volume

25262.984 mm³

closed shell

Wall min

3.164 mm

threshold — mm

Total pipeline time 183.054 ms.

Standard views

ASME Y14.3 (third angle) · sheet A3 landscape · scale 1:1. Hidden-line removal: vector (ops/hlr.js) — B-rep edges plus analytic silhouettes, occlusion-tested per sample. Views are vector — zoom or print without loss.

FRONT · 1690 visible, 1794 hidden segments
TOP · 624 visible, 3177 hidden segments
RIGHT · 1135 visible, 2342 hidden segments
ISO · 2146 visible, 1380 hidden segments

Hidden edges are drawn dashed at reduced opacity. Findings are not highlighted on these views: the packet does not carry a mapping from a check finding's entity id to a projected segment, and drawing one without it would be a guess.

Findings (1)

Findings by severity, with the stage that raised each and the entities it names
SeverityStageCodeDetailEntities
info Standard views sheet_warning drawing sheet: title-block field "legalOwner" is mandatory for ISO 7200 and is empty —

Measured properties

Measured geometric properties with units
PropertyValueUnit
Bounding box82.494 × 82.494 × 50.8mm
Volume25262.984mm³
Surface area17536.723mm²
Centroid—mm
Wall thickness (min / mean)3.164 / 18.764mm
Samples below threshold0 of 2120 at — mm
Faces18
Holes8
Cylindrical faces10
B-rep faces / edges18 / 48

computed at unit density (rho=1) — this kernel has no material model. Multiply every inertia component by a real material density [mass/mm^3] for physical inertia, and volume by that same density for physical mass.

Pipeline

Every stage this review attempted, in order. A stage that fails does not abort the packet — the remaining stages still run, so the account below is complete whatever happened.

Pipeline stages with outcome, wall time and detail
StageStatusTimeDetail
Load geometry pass 0 ms kind: session, bodyCount: 1, bodyIndex: 0
Topology inventory pass 0.716 ms faceCount: 18, edgeCount: 48, shellCount: 1
Geometry health check pass 0.01 ms tier: local, findings: 0, errors: 0
Mass properties pass 30.365 ms watertight: true, volume: 25262.984, triangles: 2120
DFM check pass 0.018 ms tier: full, findings: 0, errors: 0, duplicatesSuppressed: 0
Standard views warn 151.851 ms views: 4, scale: 1:1, visibleSegments: 5595, hiddenSegments: 8693

Drawing sheet

The same views laid out on a A3 sheet with an ISO 7200 title block, at scale 1:1. Printed at 100% this sheet is to scale.

1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C D D E E F F FRONT TOP RIGHT ISO LEGAL OWNER IDENTIFICATION NUMBER LB-0125-4H TITLE L-Bracket 0.125in REV A SHEET 1/1 DOCUMENT TYPE CLASSIFICATION DATE OF ISSUE 2026-09-03 CREATED BY CADSolver cad_design_review APPROVED BY MATERIAL mild steel MASS SCALE 1:1 SHEET FORMAT A3 LANG PROJECTION